jQuery Slider

Online UPS Double Conversion

Product Description:

From our extensive consignment, we are betrothed in presenting to our clientèle’s a supreme class Online UPS Double Conversion.

Product details:

3 Phase Input-3 Phase Output

Product Description:

With honest intentions to improve the standing we have earned in this arena, we are offering a distinct 3 Phase Input and Output.

Product details:

  • Fine built
  • Trouble free operations
  • Rugged
  • Long lasting
  • Seamless finish
  • High functionality
3 Phase Input-Single Phase Output - OL10240-3P-1P

Product Description:
Feature:


3 Phase Input And Single Phase Output

3 Phase Input-Single Phase Output: OL15240-3P-1P

Product Description:

To supply the ever rising needs of our customers, we are occupied in offering Uninterruptible Power Supply(3 Phase Input and Single Phase Output).

Product details:

  • Simple to install
  • Compact size
  • Low power consumption
  • Compact design
  • High functionality
  • Durability
Single Phase Input-Single Phase Output: OL7.5144-1P-1P
Topology True Online, Double Conversion
Type Single Phase Input-Single Phase Output
Models OL7.5144-1P-1P
Technology Double Conversion
INPUT
Input Voltage Range 175 ~ 275V AC
No of Phases 1Phase – 3 Wire (L.N.E)
UPS Input Connection Type Hard Wire
Input Frequency 47Hz – 53Hz
Battery Full Load Runtime (minutes) Depends on Load & Battery AH
OUTPUT
Output Capacity (VA) 7500
Power (watts) 6000
DC System Voltage (VDC) 144
Frequency Compatibility 50Hz ±0.1HZ
Output Voltage 230V ±1%
Load PF Range 0.8 Lagging
Output AC waveform Pure Sine Wave
Load Crest Factor 3:1
Efficiency >85%
Load Capacity >110% faulty after 300ms
Phases 1Phase – 3 Wire (L.N.E)
Output Voltage THD ?3% (Liner Load)
GENERAL
LCD / LEDs Indications Mains ON, Inverter ON, Battery Low Trip, Mains Fail, Battery Low Alarm / as per customer's specification
Alarms Power Failure, Battery Low & Overload Short Circuit
Switch One Switch control off / on power status
Maintenance By-Pass Manual By-Pass switch
Protection Battery Low & Overload ,Short circuit ,Mains UV / OV,Output UV / OV
Cooling Method Forced air cooled
Transfer Time Battery to line mode : 0 milliseconds / Line to battery mode : 0 milliseconds
DIMENSIONS
Cabinet Dimensions (HxWxL) mm 680x310x610
Cabinet Weight (kg) 90
Shipping Dimensions(HxWxL)mm 690x320x620
Shipping Weight (kg) 110
Housing Material Powder coated / painted MS
ENVIRONMENTAL
Operating Temperature Range 0°C to 50°C
Relative Humidity 95% (non-condensing)
Acoustic Noise ?51dB at 1.5 meter
Degree of Protection IP 20
BATTERY
No of Battery 12
Battery Charging Profile(Boost /Foat) Suitable according to Battery type (eg: VRLA/SMF/Wet Lead Acid Battery)
Max Charging Current(when battery is fully discharge) 10A ±2amp
SPECIAL FEATURES
Cold Start (startup in battery mode during a power failure) Cold – start operation supported
CERTIFICATIONS
Quality Certifications ISO 9001:2008
WARRANTY
Product Warranty Period 1 – year limited warranty
Since we are committed to continuous development of our products, the specifications are subject to change without notice.